this is my own brand sewing by lindaleen alhamdulillah pengguna pun sangat berpuas hati yang menggunakan since 2-3tahun lepas pun still ulang order ..terima kasih saya suka sangat jahit yes...motivate and bagi terapi minda bila product siap.. :) ini bukan sebab duit :) ok sesiapa yang berminat nak belajar buat sendiri saya juga ada buat kits and tutorial ramai yang dah beli kits saya dan dah jual product mereka sendiri.. boleh inbox saya kat fb or whasapp 0164738714 please don't call cas antarabangsa ok.. saya juga ada menjual  material-material  untuk cloth pad minky,pul fabric dan microfiber boleh like my page https://www.facebook.com/SewingByLinDaLeEn

fabric cloth diaper

Image
this entry..for friend yang asking me bout material cloth diaper..  this inner i using bamboo heavy fleece  pic nie insert lunatots...jenis microfiber please avoid this material direct to baby skin.. boleh buat kulit baby kekeringan sesuai dipakai with pocket CD bamboo fabric..sesuai juga buat insert at top layer. bamboo velour..yang nie kaler red warna lain pun ada jugak sesuai juga untuk inner CD top layer for CP&CPL yang ni pula micro fleece.. sesuai sebagai inner Cd PUL fabric nie adalah lapisan waterproof.. sesuai untuk cloth diaper dan CP sebab dia breathable fabric minky fabric.. soft ok.. sesuai jugak jadi top layer untuk cp out layer utk cd.. fabric yang sejuk. for minky fabric kebanyakannya aku menyopping di http://minkyfabrics.co.uk/ so far shipping dia ok jugak... using  pound sterling ek. service also good at time aku x received  parcel..email and inbo...

chiller

On monitoring ..RV 50% open,RV ch1 50% open,RV ch 2 100%open. seq 3,1,2.ch 1 trip on 8.06 am and 8.31(after reset).trip alarm low condenser water flow done  (because of valve at cooling tower not fully open) trip compressor surging not to be settle yet why need to RV 50% open it is can make RT high chiller 3,1 ,2 is running  continue monitoring tomorrow... how many AHU support by 1 baby chiller 180 tan running and how many AHU can support by 1 chiller 360 tan runing

cooling tower overflow

Image
cooling tower overflow Decreasing Water Use via Regular Cooling Tower Maintenance  - Regularly check the makeup water float and valve for correct setting and leakage. An incorrect    setting, or valve leakage, can cause constant cooling tower overflow resulting in substantial    excess water usage.  - To reduce water loss from cooling tower drift, water suspended in the air flow through the unit,        ensure that the unit drift eliminators are in good working order.  - Regularly check the seals in the cooling system recirculation pump(s) for leakage, repair any     leakage immediately.  - Routinely review the entire cooling system piping system for any leakage, repair immediately.  - Prevent any cooling water overflow from the system during cooling tower shutdowns by     installing a check valve on the pump discharge and ensuring that the cooling tower sump, or     cold well...